DH215A-100K
HY Tech
DH215A-100K
Our 100kW/215kWh energy storage system is designed for a variety of application scenarios, including backup power supply, peak shaving, smooth power output, and utilization of peak-valley electricity price differences. The system consists of the following key components:
Energy Storage Battery Pack
Battery Management System (BMS)
High-Voltage Control Box
Energy Storage Converter (PCS)
Energy Management System (EMS)
Low-Voltage Distribution System
Air Conditioning System
Fire Protection System The system's grid-connected voltage is 400V low-voltage coupled and grid-connected.
Model | HY-215kWh-100K | |
Rated Output Voltage | 3L/N/PE 220/380 230/400Vac | |
Rated Output Power | 100KW | |
Grid Type | Three phase | |
Battery cell type | 280Ah lP 240S | |
Battery Capacity | 768V 215kWh | |
Battery type | LiFePO4 | |
Cooling system | 3KW Industrial air conditioning | |
Dimension | 1600*1225*2400mm(L*W*H) | |
Weight | 2.5T | |
Protection Level | IP54 | |
Fire Protection Mode | Aerosol | |
Allowable Ambient Temperature | 20 50°C | |
Communication | RS485,Ethernet,CAN,ModbusTCP/RTU | |
100kW PCS | ||
DC Side Parameters | ||
Circuits | 1 | |
DC voltage range | DC 630 V-900 V | Full load |
DC maximum current | 190A | |
Rated DC power | 100 kW | |
Stabilized voltage precision | ≤+2% | |
Stabilized current precision | ≤±5% | |
Voltage limiting characteristics | Yes | |
Current limiting characteristics | Yes | |
AC Grid connected Parameters | ||
Rated power | output 100 kW | Input 100 kW |
Overload capacity | output 173 A | Input 173A |
Rated voltage | AC 400 V | |
Rated output current | 145 A | |
AC access method | Three-phase four-wire | |
Isolation mode | Non-isolated | |
Grid voltage range | 340-460 V | |
Grid frequeney range | 50 Hz/60 Hz±2.5 Hz | |
Total harmonic distortion rate of current | ≤3%(full load) | |
Power factor | -0.99-0.99 | |
Current DC component | ≤0.5% | |
Charge and discharge conversion time | <100 ms | |
AC Grid-disconnected Parameters | ||
AC grid-disconnected voltage | AC 400 V | |
AC voltage range | AC 400V±3% | |
AC grid-disconnected frequency | 50 Hz/60 Hz | |
Grid-disconnected output THDU | ≤3%(linear load) | |
Unbalanced load capacity | 100% | |
Grid-disconnected multi-machine parallel | Nonsupport |
Picture Show
Our design scheme follows the national standards and specifications as listed below:
GB 50054 Low-Voltage Electrical Power Distribution Design Code
NB/T 33015-2014 Technical Regulations for the Connection of Electrochemical Energy Storage Systems to the Power Distribution Network, etc.
CE Certifiacation Passed